3.0 Installation

Figure 3-21, DC Wiring Connection Points for MPSL Models

DC8A

DC6

DC8B

DC1

DC2

DC4

DC7

DC5

DC3

3.7.5

DC Wiring Connection Points

Figures 3-21 thru 3-23 show the connection points for the DC wiring inside the MP enclosures.

DC N

EGATIVE

C

ABLE

C

ONNECTION

TO

I

NVERTER

A

DDITIONAL

I

NVERTER

DC N

EGATIVE

C

ABLE

C

ONNECTION

DC G

ROUNDING

E

LECTRODE

C

ONNECTIONS

A

DDITIONAL

B

ATTERY

B

ANK

N

EGATIVE

C

ABLE

C

ONNECTION

B

ATTERY

B

ANK

P

OSITIVE

C

ABLE

C

ONNECTION

DC P

OSITIVE

C

ABLE

C

ONNECTION

TO

I

NVERTER

DC E

QUIPMENT

G

ROUNDING

C

ONNECTION

B

ATTERY

B

ANK

N

EGATIVE

C

ABLE

C

ONNECTION

DC C

ONNECTIONS

(

UNDER

THE

DC

D

ISCONNECT

)

DC1

Inverter’s DC Negative Cable Connection - Cable connection to Magnum inverter’s
DC negative terminal. Electrically connected to the top of the DC shunt.

DC2

Inverter’s DC Positive Cable Connection - Cable connection to Magnum inverter’s
DC positive terminal. Electrically connected to the top of the inverter’s DC disconnect.

DC3

Additional Inverter DC Negative Cable Connection - Provided so that as more inverter’s
are added, cables can be added and connected to the inverter’s DC negative terminals.

DC4

Battery Bank Negative Cable Connection - DC Negative Busbar connection (bottom
connection of DC shunt); connects cables to the battery bank’s negative terminal.

DC5

Additional Battery Bank Negative Cable Connection - Provided to connect
additional cables to the battery bank’s negative terminal when additional Magnum
inverters are installed.

DC6

Battery Bank Positive Cable Connection - Bottom of the inverter’s DC disconnect
breaker; connects the battery cable to the battery bank’s positive terminal.

DC7

DC Equipment Grounding Connection - This busbar is used as the common DC
equipment ground point for all DC equipment connected in the MP/inverter system.

DC8

DC Grounding Electrode Connections - These are the connection points for the MP/
inverter system to the DC grounding electrode. Use DC8A for #6 to #1/0 AWG wires,
and DC8B for greater than #1/0 AWG wires.