Emerson Process Management ControlWave XFC User Manual

Page 130

Advertising
background image

F-28 / Appendix F

CI-ControlWave XFC

Pipe Temp. Coefficient - Pipe coefficient of thermal expansion is entered here (Inches per
Inch-degree F).

Isentropic Exponent - Gas Isentropic Exponent is entered here. This should not be
changed unless the Gas Isentropic Exponent is known to be other than the 1.3 value given
in the 1992 American Gas Association (AGA3) Report.

Adjust Press. - Users enter Average Barometric Pressure here (psia).

Diff. Press. - Actual value in use is displayed here.

Static Pressure - Actual value in use is displayed here.

Temperature - Actual value in use is displayed here.

Spec. Gravity - Specific Gravity of the gas being measured is displayed here.

Z Flowing - Flowing compressibility Factor, Zf, generated from the AGA8 calculation
referenced to upstream conditions.

Z Base - Base compressibility Factor from the AGA8 Gross calculation.

Base Temperature - Required and Contract Base Temperate is entered here (Deg. F).

Base Pressure - Required or Contract Base Pressure is entered here (psia).

The following outputs from the AGA3 calculation are displayed:

MSCF/H - Flow rate in thousands of standard cubic feet per hour

Low Flow Cut Off - Cutoff (if the DP drops below the low flow cut off value) or OK

C Prime - Orifice Flow Constant

Fn - Numeric Conversion factor which includes Ev (the velocity of approach factor)

CD - Orifice Coefficient of Discharge

Y - Expansion Factor

Fpb - Pressure Base Factor

Ftb - Temperature Base Factor

Ftf - Flowing Temperature Facture

Fpv - Supercompressibility Factor

Fm - Additional Correction Factor

Extension - Square Root of the product of Diff. Pressure and Static Pressure (

)


Reynolds Number - Computed Pipe Reynolds Number

Advertising