Riello UPS NetMan 204 User Manual

Page 42

Advertising
background image

REGISTER

(1)

SPECIAL FLAGS (SENTR UPS)

(2)

UNIT

NUMBER ADDRESS

121

120

Byte 1 of “s = xx..” code / Byte 2 of “s = ..xx” code

Flag

122

121

Byte 1 of “c = xx..” code / Byte 2 of “c = ..xx” code

Flag

123

122

Byte 1 of “b = xx..” code / Byte 2 of “b = ..xx” code

Flag

124

123

Byte 1 of “r = xx..-..” code / Byte 2 of “r = ..xx-..” code

Flag

125

124

Byte 3 of “r = ....-xx” code / Byte 1 of “i = xx..-..” code

Flag

126

125

Byte 2 of “i = ..xx-..” code / Byte 3 of “i = ....-xx” code

Flag

127

126

Byte 1 of “a = xx..-....” code / Byte 2 of “a = ..xx-....” code

Flag

128

127

Byte 3 of “a = ....-xx..” code / Byte 4 of “a = ....-..xx” code

Flag

REGISTER

(1)

NETMAN DATA

UNIT

NUMBER ADDRESS

129

128

Firmware version

Integer

130ч131

129ч130

(1)

The register number

n must be addressed n-1 in the data packet.

(2)

In order to decode these registers, please refer to the UPS manual.

UPS:

C

OMMANDS CODES

CODE

COMMAND

1 (0x0001)

Command Shutdown

2 (0x0002)

Command Shutdown and Restore

3 (0x0003)

Delete Command (code 1, 2, 12)

12 (0x000C)

UPS on Bypass

20 (0x0014)

Test Battery

22 (0x0016)

Test Panel

- 42 -

Advertising