User’s Manual of IGT-90x

The 802.3ah Loop Back Test Web page includes the following configurable data:

802.3ah Loop Back Test

Send Packet Number

Allow input the number for packet send and the available options is 1 to 255.

Default is 16.

Packet Length

(Not include CRC)

Allow input the number for Packet Length and the available options is 60 to 1514.
Default is 60.

Apply Button

Press this button for save current configuration of Industrial Managed Media
Converter.

Refresh Button

Press “Refresh” button to refresh current status.

802.3ah Loop Back Test Result

Result

Display the 802.3ah Loop Back Test Result. Fail or Pass.

Table 4-16

Descriptions of the 802.3ah Loop Back Test Web Page Screen Objects

1. The 802.3ah function must work with manageable device that supports 802.3ah function.

2. Please use the PLANET GT-80X / GT-90X / IGT-90X as the Remote device.