Power Input

12 to 48V DC

Redundant power with polarity reverse protection function

Power Consumption

7.7 Watts/ 26 BTU (maximum)

Operating Temperature

-10~60

Degree C

-30~75

Degree C

-10~60

Degree C

-30~75

Degree C

-30~75

Degree C

Operating Humidity

5~90% non-condensing

Storage Temperature

-20~85

Degree C

-40~85

Degree C

-20~85

Degree C

-40~85

Degree C

-40~85

Degree C

Storage Humidity

5~90% non-condensing

Dimension (W x D x H)

13.5 x 8.5 x 3.2 mm

Weight

423g

Installation

DIN rail kit and wall mount ear

Management and Layer 2 Features

Management Interface

WEB / SNMP v1, v2c

Port Configuration

Port disable/enable

Auto-negotiation 10/100/1000Mbps Full and Half duplex mode selection.

Flow Control disable / enable. Bandwidth control on each port.

VLAN

IEEE 802.1q Tagged Based VLAN , 4K VLAN ID, up to 16 VLAN groups

Q-in-Q VLAN

QoS

Traffic classification based on :

• 802.1p priority
• IP DSCP field in IP Packet
• IP Address

Bandwidth Control

Ingress / Egress bandwidth control

• Rate range: 512kbps to 500Mbps

Storm control

• Broadcast / Multicast / Unknown Unicast packet

Standard Conformance

Emissions

FCC Class A, CE Class A

Standard

IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TX

IEEE 802.3z Gigabit SX/LX

IEEE 802.3ab Gigabit 1000T

IEEE 802.3x Flow Control and Back pressure

IEEE 802.1p Class of service

IEEE 802.1Q VLAN Tagging

IEEE 802.3ah OAM

Stability

IEC60068-2-32 (Free fall)

IEC60068-2-27 (Shock)

IEC60068-2-6 (Vibration)

* =Depend on the various SFP modules