7.4.16 Pass-through Formatted Block for Function 22

Block 9960: Pass-through Formatted Block for Function 22

Block 9960: Request from Module to Processor

Offset

Description

0

Block ID 9960

1

Block ID 9960

2

Number of word registers in Modbus data set

3

Starting address for Modbus data set

4 to 53

Modbus Data

The ladder logic will be responsible for parsing and copying the received
message and performing the proper control operation as expected by the Client
device. The processor must then respond to the pass-through control block with
an output image write block with the following format.

Block 9960: Response from Processor to Module

Offset

Description

0

Block ID 9960

1 to 239

Spare

This will inform the module that the command has been processed and can be
cleared from the pass-through queue.

7.4.17 Pass-through Formatted Block for Function 23

Block 9961: Pass-through Formatted Block for Function 23

Block 9961: Request from Module to Processor

Offset

Description

0

Block ID 9961

1

Block ID 9961

2

Number of word registers in Modbus data set

3

Starting address for Modbus data set

4 to 53

Modbus Data