7.4.19 Set Module Time Using Received Time Block

Block 9972: Set Module Time Using Received Time Block

This block will use the time information of the processor to set the module time.

Block 9972: Request from Processor to Module

Offset

Description

0

Block ID 9972

1

Year (0-9999)

2

Month (1-12)

3

Day (1-31)

4

Hour (0-23)

5

Minutes (0-59)

6

Seconds (0-59)

7

Milliseconds (0-999)

8 to 239

Spare

Block 9972: Response from Module to Processor

Offset

Description

0

Block ID 9972

1

Write Block ID

2

Return code 0=OK, -1=error

3 to 239

Spare

7.4.20 Pass Module Time to Processor Block

Block 9973: Pass Module Time to Processor Block

This block will use the time information of the module to set the processor time.

Block 9973: Request from Processor to Module

Offset

Description

0

Block ID 9973

1 to 239

Spare

Block 9973: Response from Module to Processor