Function mode – Hitachi SJ300 User Manual

Page 12

Advertising
background image

1- 9

Function mode

Code

Function name

SJ300 Setting range

Initial data
-FE/-FU/-F

Note

P001

Option1 operation selection
on error

00(TRP)/01(RUN)

00

P002

Option2 operation selection
on error

00(TRP)/01(RUN)

00

P010

Feed-back option selection

00(Invalid)/01(Valid)

00

P011

Encoder pulse number
setting

128.-9999./1000-6500(10000-65000) (pulse)

1024

P012

Control mode selection

00(ASR mode)/01(APR mode)

00

P013

Pulse train input mode
selection

00(Mode 0)/01(Mode 1)/02(Mode 2)/03(Mode 3)

00

P014

Orientation stop position
setting

0.-4095.

0.

P015

Orientation speed setting

0.00-99.99/100.0-120.0(Hz)

5.00

P016

Orientation direction
selection

00(Forward)/01(Reverse)

00

P017

Orientation completion range
setting

0.-9999./1000(10000) (pulse)

5

P018

Orientation completion delay
time setting

0.00-9.99(s)

0.00

P019

Electronic gear position
selection

00(Feedback)/01(Reference)

00

P020

Electronic gear numerator of
ratio setting

0.-9999.

1.

P021

Electronic gear denominator
of ratio setting

0.-9999.

1.

P022

Position control feed-forward
gain setting

0.00-99.99/100.0-655.3

0.00

P023

Position control loop gain
setting

0.00-99.99/100.0

0.50

P025

Compensation of secondary
resistor selection

00(Invalid)/01(Valid)

00

P026

Over-speed detect level
setting

0.00-99.99/100.0-150.0(%)

135.0

P027

Speed-error over detect level
setting

0.00-99.99/100.0-120.0(Hz)

7.50

P031

Digital input option input
mode selection ( Acc/Dec)

00(operator)/01(option1)/02(option2)

00

P032

Stop position setting for
orientation input mode
selection

00(operator)/01(option1)/02(option2)

00

P044

DeviceNet running order of
monitoring timer setting

0.00-99.99s

1.00

P045

Setting in action of abnormal
communication

00(trip)/01(trip after deceleration stop)/02(invalid)/

03(free-run)04(deceleration stop)

0.

P046

Output assemble instance
Number setting

20,21,100

21

P047

Input assemble instance
Number setting

70,71,101

71

P048

Detect of idol mode for
motion setting

00(trip)/01(trip after deceleration stop)/02(invalid)/

03(free-run)04(deceleration stop)

01

P049

Pole setting of rotation speed

0-38(even only)

0

U001

User1 selection

no/d001-P049 <-P032>

no

U002

User2 selection

no/d001-P049 <-P032>

no

U003

User3 selection

no/d001-P049 <-P032>

no

U004

User4 selection

no/d001-P049 <-P032>

no

U005

User5 selection

no/d001-P049 <-P032>

no

U006

User6 selection

no/d001-P049 <-P032>

no

U007

User7 selection

no/d001-P049 <-P032>

no

U008

User8 selection

no/d001-P049 <-P032>

no

U009

User9 selection

no/d001-P049 <-P032>

no

U010

User10 selection

no/d001-P049 <-P032>

no

U011

User11 selection

no/d001-P049 <-P032>

no

U012

User12 selection

no/d001-P049 <-P032>

no

(Note 1) P044-P049 are displayed on a 0.4-55kW model.

User selection

Option

Advertising
This manual is related to the following products: