Function mode – Hitachi SJ300 User Manual

Page 14

Advertising
background image

1- 11

Function Mode

Code

Function name

L300P Setting range

Initial data

-FE/-FU/-FR

N o t e

A001

Frequency setting selection

00(VR)/01(terminal)/02(operator)/03(RS485)/

04(option1)/05(option2)

01/01/00

A002

Operation setting selection

01(terminal)/02(operator)/03(RS485)/04(option1)/05(option2)

01/01/02

A003

Base frequency

30. - Maximum. frequency(Hz)

50./60./60.

A203

Base frequency, 2nd motor

30. - 2

nd

M aximum. frequency (Hz)

50./60./60.

A004

Maximum frequency

30. - 400. (Hz)

50./60./60.

A204

Maximum frequency, 2nd

motor

30. - 400. (Hz)

50./60./60.

A005

AT terminal selection

00( Changing of O and OI with AT terminal)/01(Changing of O and O2

with AT terminal)

00

A006

02 selection

00(single)/01(auxiliary speed of O, OI) [no reversible]

/02(auxiliary speed of O, OI [reversible]

00

A011

0 start

0.00-99.99/100.0-400.0 (Hz)

0.00

A012

0 end

0.00-99.99/100.0-400.0 (Hz)

0.00

A013

0 start rate

0.-100.0 (%)

0.

A014

0 end rate

0.-100.0(%)

100.

A015

0 start selection

00 (external starting frequency)/01( OHz)

01

A016

O, OI, O2 sampling

1.-30.(times)

8.

A019

Multi-speed selection

00(binary : range is to 16 stage speed with 4 terminals)/01(bit : range

is to 6 stage speed with 5 terminals)

00

A020

Multi-speed 0

0.00, starting frequency-maximum. frequency(Hz)

0.00

A220

Multi-speed 0, 2

nd

motor

0.00, starting frequency-2

nd

maximum frequency(Hz)

0.00

A021

Multi-speed1

0.00, starting frequency-maximum frequency(Hz)

0.00

A022

Multi-speed2

0.00, starting frequency-maximum frequency(Hz)

0.00

A023

Multi-speed3

0.00, starting frequency-maximum frequency(Hz)

0.00

A024

Multi-speed4

0.00, starting frequency-maximum frequency(Hz)

0.00

A025

Multi-speed5

0.00, starting frequency-maximum frequency(Hz)

0.00

A026

Multi-speed6

0.00, starting frequency-maximum frequency(Hz)

0.00

A027

Multi-speed7

0.00, starting frequency-maximum frequency(Hz)

0.00

A028

Multi-speed8

0.00, starting frequency-maximum frequency(Hz)

0.00

A029

Multi-speed9

0.00, starting frequency-maximum frequency(Hz)

0.00

A030

Multi-speed10

0.00, starting frequency-maximum frequency(Hz)

0.00

A031

Multi-speed11

0.00, starting frequency-maximum frequency(Hz)

0.00

A032

Multi-speed12

0.00, starting frequency-maximum frequency(Hz)

0.00

A033

Multi-speed13

0.00, starting frequency-maximum frequency(Hz)

0.00

A034

Multi-speed14

0.00, starting frequency-maximum frequency(Hz)

0.00

A035

Multi-speed15

0.00, starting frequency-maximum frequency(Hz)

0.00

A038

Jogging frequency

0.00, starting frequency-9.99(Hz)

1.00

A039

Jogging selection

00(free-run on JG stop / invalid on running) / 01(stop decelerating on

JG stop / invalid on running) / 02(DC braking on JG stop/invalid on

running) / 03(free-run on JG stop/valid on running[JG after stop

decelerating]) / 04 (stop decelerating on JG stop/valid on running) /

05 (DC braking on JG stop/valid on operating)

00

A041

Torque boost selection

00 (manual torque boost) / 01 (automatic torque boost)

00

A241

Torque boost selection, 2

nd

motor

00 (manual torque boost) / 01 (automatic torque boost)

00

A042

Manual torque boost

0.0-20.0(%)

1.0

A242

Manual torque boost, 2

nd

motor

0.0-20.0(%)

1.0

A043

Manual torque boost point

0.0-50.0(%)

5.0

A243

Manual torque boost point, 2

nd

motor

0.0-50.0(%)

5.0

A044

1

s t

control

00/(VC)/01(VP1.7power)/02(free V/f setting)

00

A244

2

nd

control

00/(VC)/01(VP1.7power)/02(free V/f setting)

00

A045

Output voltage gain

20. - 100. (%)

100.

A051

DC braking selection

00(invalid)/01(valid)

00

A052

DC braking frequency

0.00-60.00(Hz)

0.50

A053

DC braking wait time

0.0 - 5.0(s)

0.0

A054

DC braking power

0. - 70. (%)

0.

A055

DC braking time

0.0 - 60.0(s)

0.0

A056

DC braking edge/level

selection

00(edge action)/01(level action)

01

A057

DC braking power

(starting time)

0. - 70. (%)

0.

A058

DC braking time

(starting time)

0.00-60.0(s)

0.0

A059

DC carrier frequency

0.5-12(kHz) Derating <0.5-8(kHz)>

3.0

(Note) < > indicate the setting range of 90 to 132kW

Base setting

Multistage

speed,jogging frequency setting

V/f characteristic

Direct current braking

Analog input setting

Advertising
This manual is related to the following products: