5- 6

(How to remove cooling fan for steel case)

•

Remove

terminal cover

and

front cover

.

‚

Reconfirm that the charge lamp is turned OFF.

ƒ

Remove the all screws of the cooling fan case and pull out like following figure.

„

Remove the connector for fan connection.

(How to fix cooling fan for steel case)

•

Pay attention to the direction of the cooling fan.

‚

Connect the fan connector to J21

or

J22 or J23 or J24 (depends on the model) on the power PCB.

ƒ

Fix the

cooling fan case

to the inverter main body.

„

Fix the front cover and terminal cover.

(2) DC bus capacitor

Big capacitance of electrolytic capacitors are used in a DC bus line of the inverter as a smoothing circuit.
Due to the chemical reaction inside the capacitor, its lifetime highly depends on the ambient temperature

and usage condition. Replacement is recommended to be done in 5 years under normal usage condition.
Also, it should be anyway replaced with new ones when there is any abnormality is found or its capacity

becomes less than 85% of its rated capacitance.

(How to remove DC bus capacitor for mold case)

•

Remove terminal cover.

‚

Reconfirm that the charge lamp is turned OFF.

ƒ

Remove blind cover.

„

Remove all the screws connecting capacitor PCB and power PCB.

…

Pull the capacitor PCB downwards.

Advertising