Table 26

lists the various Fusion UV Systems Irradiator models and cooling method.

NOTE: All air flow specifications assume standard air density of 1.20 kg/

m

3

(0.075 lbs/ft

3

). Remote blower specification must be corrected for air density

variations at customer site.

Cooling:

I300M/I310M/I310M-D/I311N/I311M-D: Requires a remote pressure blower.

I300MB/I310MB/I310MB-D:

K300M modular blower mounts on top of
the irradiator and is powered by the
P300M/P300MQ power supply.

Reflector:

Polished and brightened aluminum elliptical reflector with protective
aluminum oxide coating. Focus is 53.3 mm (2.1 inches) below
irradiator base rails.

The standard reflector has R500 coating. Optional reflectors have
R350 or Dichroic (cold) coatings.

Interlocks:

Photoresistor assembly

Air pressure switch

Weight:

12.0 kg (26.5 lbs) with modular blower.

7.3 kg (16.0 lbs) without modular blower

Table 26. Irradiator Models and Details

System

Power Supply

Irradiator Designation

Cooling Method

F300S/
F300SQ

P300M/P300MQ/
P300MT

I300M/I310M/I310M-D/
I311M/I311M-D

Remote cooling (Note 1) 2.8 m

3

/min

(100 cfm) at 695 Pa (2.8 H

2

O) inlet

pressure

I300MB/I310MB

K300M Modular Blower

Table 27. Power Inputs from P300M/P300MQ/P300MT

Magnetron Power:

695 mA+45mA @ 3900 VDC

Filament Voltage:
STANDBY

115 VAC

100% Power

85 VAC

Blower Voltage

2.0 A @ 200-240 VAC