Table 38. troubleshooting and fault diagnosis, Ignitor bulb removal/replacement – Fusion F300S User Manual

Page 150

Advertising
background image

Ignitor Bulb

150

F300S/F300SQ Ultraviolet Lamp System

Ignitor Bulb Removal/Replacement

1. Replace the ignitor bulb only if the lamp does not start consistently and all other

indications are normal.

Table 37. Routine Operations Associated with Ignitor Bulb

(Refer to

Table 12 on page 59

for other operational information.)

Time

Power

Switch

Lamp Control

Lamp Control

Flasher

Operation

0 sec
2-4 sec

8 sec

On

Lamp on

Green flash

Steady green

Start HV transformers
Ignitor bulb lights

UV bulb ignites; ignitor
bulb turns off
UV bulb at full power

0 sec

10 sec

12-18 sec

18-20 sec

From lamp off
to lamp on

Slow flash yellow

Fast flash green

Steady green

Ignitor bulb lights

UV bulb ignites; ignitor
bulb turns off

UV bulb at full power

Table 38. Troubleshooting and Fault Diagnosis

(Refer to

Table 18 on page 69

for other operational information.)

Operation

Signal/Other Symptoms

Possible

Cause

Corrective Action

Switch from
Standby to On

LAMP OUT indicator lights,
or UV output is weak, or
UV bulb does not light

Ignitor bulb
position

The lead from the base of the
ignitor bulb should be inserted
up to its outer sleeve into the
waveguide launcher

Ignitor bulb

Replace ignitor bulb

RF INTLK indicator lights

Ignitor bulb
faulty

Replace ignitor bulb

Advertising