F300S/F300SQ Ultraviolet Lamp System

2. Turn the Master POWER switch ON and press the LAMP ON switch.

3. The system will now operate from remote switches. Remote switch functions are

virtually the same as front panel switch functions.

Operation with Remote Controls

KEY:

S- Switch position does not matter.

Quick Restart Option (QRO)

The Quick Restart Option (QRO) provides the ability to restart the lamp at any time,
even immediately after the lamp has been switched to Standby mode. Thus, the
mandatory 18-second restart cycle time associated with routine operation has been
eliminated. The QRO may be installed at the time of the P300MQ power supply
construction or may be retrofitted into P300M power supplies in the field by trained
personnel.

Table 13. Remote Switch Functions

Remote Switch

Equivalent Panel

Control

Lamp Status

Switch Open

Switch Closed

Lamp ON

Lamp ON

Standby

Lamp ON

Lamp RESET

LAMP OFF/RESET

Default to lowest state

LAMP OFF/RESET

Table 14. Operation with Remote Controls

Panel Controls on Master

Remote

Switches

Power

Lamp Control

Lamp ON

Lamp Status

Off/Reset

S

S

Off/Reset

ON

LAMP OFF/RESET

S

LAMP OFF/RESET

ON

ON

Remote RESET
Switch CLOSED

LAMP OFF/RESET
(overrides remote Lamp
ON switch)

ON

STANDBY

OPEN

STANDBY

CLOSED

ON

OPEN

CLOSED

Lamp ON

Advertising