F300S/F300SQ Ultraviolet Lamp System

QRO Transformer Taps (FOR QRO only)

When the Quick Restart Option is installed, the QRO transformers must be tapped
according to the frequency and voltage specifications of the customer. Should these
specifications change, or if a transformer is replaced, the transformer should be tapped
as follows:

50 Hz

200

200

208

220

220, 240

240

60 Hz

200

200

208

220

240

220, 240

Table 10. QRO Transformer Taps (Optional)

Power

QRO Transformer

Primary Front Tap

Primary and

Secondary Rear Taps

50 Hz

200

200V

50 Hz

208

220

240V

240

60 Hz

200

200V

60 Hz

208

220

240V

240

Table 9. High Voltage Transformer Taps (continued)

Power

HV Plate

Transformer