Figure 45. p300m/p300mq hv wiring, Top view side view – Fusion F300S User Manual

Page 111

Advertising
background image

Installation, Operation, and Maintenance Manual # 509252 Rev R

111

1. Disconnect all power, discharge the high voltage capacitors, and disconnect all

leads from the transformer terminals.

2. Unbolt the transformer from the power supply chassis.

3. To replace the transformer, reverse the steps, being certain that terminals are in

the correct locations. Refer to

Table 20, “Transformer Terminal Orientation,” on

page 112

that follows.

CAUTION: Transformers must be securely mounted to the chassis to
provide adequate transformer grounding.