System components, Control – Fusion F300S User Manual

Page 17

Advertising
background image

Installation, Operation, and Maintenance Manual # 509252 Rev R

17

Electrical inputs to the lamp module are provided by a high voltage/control cable with
a quick-connect fitting which supplies power for the magnetron, filament transformer
and the interlock circuitry.

System Components

The basic F300S/F300SQ system consists of the following items:

• A P300M/P300MQ/P300MT power supply

• An HV Cable H340 (no modular blower)

• An HV Cable H341 (with modular blower)

• An I300 series irradiator

• An RF detector cable H790

• An RF-1 detector

In addition, the user must supply the following if not provided by Fusion UV Systems:

• Cooling for the irradiator, if no modular blower is provided. (See

Appendix A,

“Specifications”

and

Appendix C, “Outline Drawings”

for irradiator cooling

requirements.)

• Mechanical mounting of the lamp modules over a substrate, conveyor, or other

transport mechanism

• Light shield surrounding the lamps

• Exhaust system for the light shield

• Any desired interlock mechanisms (see

Chapter 3 on page 39

)

• Electrical wiring of the power supply into the plant electrical system

Control

The control system of the F300S/F300SQ provides precise control of high voltage and
filament voltage supplies. The control board also monitors cooling air pressure,
detection of RF, power levels, bulb ignition, and interlocks such as transformer
thermal switches. If a problem arises, the control system turns off all high voltage
power to the lamp and flashes a fault LED indicator on the power supply control panel.

Inputs for customer ON/OFF control are available. Outputs allow detection of
STANDBY or LAMP ON operation, or of interlock failures.

Advertising
This manual is related to the following products: