F300S/F300SQ Ultraviolet Lamp System

Figure 12. F300/F300SQ Single-unit Installation

Programming

Select one unit as the Master. Set S1-1, 1-2, 1-3, and 1-5 of this unit to “YES.” For
programming switch S1 setting definitions, see

Figure 11

.

Irradiator Cable H340 Connections

Non-blower version cable H340 connects to J103 and J104 on the power supply; and
to J10 on the irradiator. All connectors are labeled, and keyed so they cannot be
inadvertently interchanged.

Blower version cable H341 connects to J103 and J104 on the power supply, and to J10
and J11 on the irradiator. All connectors are labeled, and keyed so they cannot be
inadvertently interchanged.