Maintenance & Service

Troubleshooting

4

4-3

35360A TRACKER Display will not turn on (display will not light)

Figure 4-1.

No Display Flowchart

No

Yes

No

Yes

No

Yes

Yes

No

Return 35360A TRACKER Display

Replace 35360A TRACKER

Fuses OK?

Check AC line fuses at rear panel

of 35360A TRACKER Display.

AC line voltage present?

Verify voltage present at AC line

receptical by connecting and

powering some other device.

Commence operation from AC line

power or charge batteries.

35360A TRACKER Display

Connect 35360A TRACKER

Display to an AC power source

and press the POWER key.

35360A TRACKER Display's

VFD does not illuminate when

POWER key is pressed.

Operating from AC power source?

When attempting to turn the instrument on,

firmly press the POWER key and hold

for approximately one second. Always

allow several seconds between retries.

NOTE

When powering the 35360A TRACKER Display from

an AC line, always use a 3-wire grounding type line cord

h

as the one supplied with the 90100 TRACKER System.

In addition, only connect the 35360A TRACKER Display to

AC power outlet employing a third wire safety

d

Always turn the 35360A TRACKER Display's power off

prior to connecting or disconnecting the interface

bl

Failure to do so may result in an electrical

h

k

The Model 35360A TRACKER Display and 35300A

Detector contain no internal operator serviceable

Disassembly of either unit could result in electrical

h

k

WARNING

Display's AC line fuses.

to Keithley for repair.

VFD illuminates?