2 switch functions and default settings – MRV Communications EM316SW-XY User Manual

Page 21

Advertising
background image

Fiber Driver

®

EM316SW-XY


PN 1288003-001, Rev D2

13

3.3.2 Switch Functions and Default Settings


The switch block number is not sequential on the module. Carefully verify the switch block
number and placement before changing switch settings.

Switch Block 1*

DIP Switch

DIP Switch Name Setting Description

ON (up)

Control by NM is enable

1

MANG EN

OFF (down)

Control be NM is disable

ON (up)

LIN enable

2

LIN EN

OFF (down)

LIN disable

ON (up)

3

AGING F

OFF (down)

NOT USED

ON (up)

4

OFF (down)

NOT USED

ON (up)

5

MODE1

OFF (down)

ON (up)

6

MODE0

OFF (down)

See table below

ON (up)

P1 Auto Negotiation is enable

7

ANEG

OFF (down)

P1 Auto Negotiation is disable

ON (up)

P4 Auto Negotiation is enable

8

ANEG2

OFF (down)

P4 Auto Negotiation is disable



SW1-5, SW1-6 – Operational Modes

DIP Switches

Mode

MODE1

MODE0

Port Grouping

Dual Repeater

ON

ON

Fiber Repeater: ports P2 & P3
Copper Repeater: ports P1 & P4

Dual Converter
(default mode)

ON OFF

Converter 1: ports P1 & P2
Converter 2: ports P3 & P4

Redundant Link

OFF

ON

Redundant: fiber optic ports P2 & P3
Local: copper port P1
Unused: copper port P4

Mixed-Media Switch

OFF

OFF

All ports (P1, P2, P3, P4)