Each module may be given a descriptive name with the command below. The show
command follows with the new name line in bold font. Each new slot name may also be
displayed with individual show commands in each slot context.

fiberdriver(slot/1.3)# description MY-SW-XY
fiberdriver(slot/1.3)# up
fiberdriver(chassis/1)# show
Model: NC316BU-16
Name: NC316BU-1
Temp(C): 25
Temp Min(C): 5
Temp Limit(C): 55

PS1: DC Bad PS2: AC Good
Fan1: good Fan2: good
Fan3: good
Chassis Traps: on Slot Change Traps: on Module Specific Traps: on
Port Traps: on Link Traps: on Loopback Traps: on
LIN Traps: on Port Change Traps: on Port Diags Traps: on

Number Of Slots: 16
Hardware Revision: 1

Slot Model Name Serial Number
==== =============== ====================== ============================
1.2 EM316LNXNM-OT EM316LNXNM-OT at 1.2 00:20:1a:02:48:28
1.3 EM316SW-XY MY-SW-XY N/A

fiberdriver(chassis/1)#