2 configuring system parameters – MRV Communications EM316SW-XY User Manual

Page 44

Advertising
background image

Fiber Driver

®

EM316SW-XY


PN 1288003-001, Rev D2

36


4.3.4.2 Configuring System Parameters




Once the mode is changed, the prompt also changes. Change the SUPER user password using
the "username" command.

fiberdriver(config)# username admin password <new password>


Set the IP configuration using the "ip" command group. Set IP address and IP mask information
using the following command.

fiberdriver(config)# ip interface 192.168.1.14/24


The IP address (192.168.1.14) and the 24-bit netmask (/24) are instructive examples. Use the
IP address and netmask appropriate for the EM316LNXNM-OT on your network. Classless
Inter-Domain Routing (CIDR) notation is used to specify the address “192.168.1.14” and the
address mask “24” corresponding to 255.255.255.0.


Set specific gateway information using the following command:

fiberdriver(config)# ip default-gateway 192.168.1.1


The IP information configured does not load until restarting the system or using the command:

ip interface update


Use the following command to save the configuration into permanent (non-volatile) storage:

fiberdriver(config)# write file
fiberdriver(config)# exit


The system does not automatically save configurations to permanent storage. Use the write
file

command to save a configuration before restarting the system. Now the IP configuration is

complete. The default SNMP community names are "public" for read and "private" for write.

Use the description command to change names of the chassis, slot, and port. Use the show
command to verify the change. Chassis names are limited to nine characters.

Advertising