9 sfp port commands, 1 “loopback, 2 “lin – MRV Communications EM316SW-XY User Manual

Page 65

Advertising
background image

Fiber Driver

®

EM316SW-XY


PN 1288003-001, Rev D2

57

4.3.9 SFP Port Commands


The following commands are specific to the SFP ports on the EM316SW-XY module.

4.3.9.1 “loopback”


This command activates the loopback function on the target port.


4.3.9.2 “lin”


This command activates or deactivates the Link Integrity Notification function.

fiberdriver(port/1.3.2)# loopback
fiberdriver(port/1.3.2)# fdrd[60]|TRAP| warn|Jan 01 21:30:07 Port 1.3.2
Loopback On, Chassis Name: NC316BU-16 Slot Name: EM316SW-XY at 1.3 Port Name: SFP at
1.3.2

fiberdriver(port/1.3.2)#
fiberdriver(port/1.3.2)# no loopback
fiberdriver(port/1.3.2)# fdrd[60]|TRAP| warn|Jan 01 21:30:22 Port 1.3.2
Loopback Off, Chassis Name: NC316BU-16 Slot Name: EM316SW-XY at 1.3 Port Name: SFP
at 1.3.2

fiberdriver(port/1.3.2)#

fiberdriver(port/1.3.2)# lin
fdrd[60]|CORE| warn|Jan 01 21:30:33 1.3.1: Auto-adjusted PortLIN -> enable Ok
fdrd[60]|CORE| warn|Jan 01 21:30:33 1.3.3: Auto-adjusted PortLIN -> enable Ok
fiberdriver(port/1.3.2)# fdrd[60]|TRAP| warn|Jan 01 21:30:34 Port 1.3.1 LIN
On, Chassis Name: NC316BU-16 Slot Name: EM316SW-XY at 1.3 Port Name: RJ-45 at 1.3.1
fdrd[60]|TRAP| warn|Jan 01 21:30:34 Port 1.3.2 LIN On, Chassis Name: NC316BU-
16 Slot Name: EM316SW-XY at 1.3 PortName: SFP at 1.3.2
fdrd[60]|TRAP| warn|Jan 01 21:30:34 Port 1.3.3 LIN On, Chassis Name: NC316BU-
16 Slot Name: EM316SW-XY at 1.3 PortName: SFP at 1.3.3

fiberdriver(port/1.3.2)#
fiberdriver(port/1.3.2)# no lin
fdrd[60]|CORE| warn|Jan 01 21:30:42 1.3.1: Auto-adjusted PortLIN -> disable Ok
fdrd[60]|CORE| warn|Jan 01 21:30:42 1.3.3: Auto-adjusted PortLIN -> disable Ok
fiberdriver(port/1.3.2)# fdrd[60]|TRAP| warn|Jan 01 21:30:46 Port 1.3.1 LIN
Off, Chassis Name: NC316BU-16 Slot Name: EM316SW-XY at 1.3 Port Name: RJ-45 at 1.3.1
fdrd[60]|TRAP| warn|Jan 01 21:30:46 Port 1.3.2 LIN Off, Chassis Name: NC316BU-
16 Slot Name: EM316SW-XY at 1.3 Port Name: SFP at 1.3.2
fdrd[60]|TRAP| warn|Jan 01 21:30:46 Port 1.3.3 LIN Off, Chassis Name: NC316BU-
16 Slot Name: EM316SW-XY at 1.3 Port Name: SFP at 1.3.3

fiberdriver(port/1.3.2)#

Advertising