Target MAC Address: The MAC Address of the peer unit that will be at the other end of the

wireless link. This is used by the system to ensure the unit establishes a wireless link to the

correct peer.

The MAC Address can be found embedded within the serial number of the unit. The last six

characters of the serial number are the last three bytes of the unit’s MAC address.

(Note: A PTP 600 Series system is shipped as a pair of units with pre-loaded correct MAC

addresses. MAC addresses will only need to be entered if an existing unit has to be replaced

in the field or the units configuration has been erased).

Master Slave Mode: At this point it is necessary to decide which end will designate a Master.

The Master unit is the controlling unit with respect to the point-to-point link and its

maintenance. The master transmits until the link is made, while the Slave listens for its peer

and only transmits when the peer has been identified.

Link Mode Optimization: Optimizes the link behavior according to the type of traffic that will

be bridged.

Max Transmit Power: This attribute controls the maximum transmit power the unit is

permitted to use when installing and executing the wireless link. The maximum setting for a

particular region or country is controlled by the License Key.

Ranging Mode: During installation the wireless units perform automatic ranging. The ranging

mode allows the installer to control the behavior of the system’s automatic ranging algorithms.

The default value is 0 to 40 km

21

(0 to 25 miles). If the installer is required to install a link of

greater than 40 km (25 miles) then the ranging mode attribute MUST be configured to ‘0 to

100km’ (0 to 62 miles) or ‘0 to 200km’ (0 to 124 miles) mode depending on the range of the

link.

Target Range: Installers that know the range between the two wireless units to within

± 1 km

can use the target range mode. The main advantage of the target range mode is that it

reduces the time taken by the units to range. To use the target range mode the installer

MUST select Target Range as the ranging mode and enter the approximate range in km in

the Target range data entry field at both ends of the link.

21

If preferred PTP 600 Series Bridge range functions can be configured to operate in miles, see the

page in section 8.3.14.