14.6 Lightning

Protection

14.6.1 Overview

Section 11 in the main body of this manual contains the requirements for the Motorola PTP

600 Series deployment. This section details the additional requirements for the deployment of

E1/T1.

14.6.2 Recommended Additional Components for E1/T1 Installation.

The recommended components below are in addition to those listed in section 11, the extra

components required for the E1/T1 installation are:

• Screened Cat 5 Cable
• Surge Arrestor Units — Transtector type ALPU-ORT, 4 required per link.

(

www.transtector.com

)

• RJ45 screened connectors
• 8 AWG Grounding Cable

For a description of Zone A and Zone B refer to section 11.

Zone A

Zone B

Earth ODU

Mandatory

Mandatory

Screen Cable

Mandatory

Mandatory

Surge Arrestor Unit ALPU-ORT at ODU

Mandatory

Mandatory

Earth Cable at Building Entry

Mandatory

Mandatory

Surge Arrestor Unit ALPU-ORT at Building Entry

Mandatory

Mandatory

Table 22 - Protection Requirements