Motorola MotoWI4 PTP 600 Series User Manual

Page 67

Advertising
background image

65

The following behavior should be noted:

• When first started up and from time to time, the Master unit will carry out a band scan to

determine which channels are not in use. During this time, between 10 and 15 seconds,

the Master unit will not transmit and as a consequence of this neither will the Slave unit.

During this time the installation tone on the master unit will drop back to the band scan

state, and the Slave unit will drop back to the Scanning state with the pitch of the tone set

to the background noise level. Alignment of the unit should cease during this time.

• The master unit can take up to 60 seconds in 0-40km (0-25 miles) mode, 90 seconds in

0-130km (0-81 miles) mode and 120 seconds in 0-200km (0-124 miles) mode to

determine the range of the link being installed

13

. The Master unit will remain in the

Scanning state until the range of the link has been established. The Master unit will only

move to the Synchronized state when the range of the link has been established.

• If, at the end of the ranging period, the Registered state is not achieved due to

interference or other reasons, the Master unit will retry twice more on the same channel

before moving to another available channel. Should this occur it might take a number of

minutes to establish a link in the Registered state.

• The Slave unit does not have a ranging process. The slave unit will change to the

Synchronized state as soon as the wanted signal is demodulated.

When the alignment process is complete the installer MUST REMEMBER TO DISARM BOTH

UNITS in the link as described in section 8.3.4. This is necessary in order to:

• Turn off the audible alignment aid
• Enable Adaptive Modulation
• Fully enable Advanced Spectrum Management with i-DFS
• Clear unwanted installation information from the various systems statistics
• Store the link range for fast link acquisition on link drop
• Enable higher data rates

13

If the unit is operating where mandatory radar avoidance algorithms are implemented the ranging

behaviour for the PTP 600 Series Bridge may be affected. The Master has to monitor the initially

chosen channel for 60 seconds to make sure it is clear of radar signals before transmitting. If a radar

is detected during any of the installation phases a further compulsory 60 seconds channel scan will

take place as the master unit attempts to locate a new channel that is free of radar interference