The user should ensure that the correct image is shown before pressing the “Program

Software Image into Non-Volatile Memory” button. Once this button has been pressed the

image is stored into non-volatile memory, this process can take up to 60 seconds and must

not be interrupted.

If the upgrade process is interrupted during the erasure of the image bank, or during the

reprogramming of the image bank, the image bank will be left in a corrupt state. If this occurs

the software must be reloaded. All software images that are stored in non-volatile memory are

protected via the use of CRCs. If the software detects an invalid CRC the image bank is

marked as ‘corrupt’ and the 600 Series bridge boot code will boot the fixed software image. If

this occurs the user must attempt to reload the correct version of software.

During the write process the progress of the upgrade is displayed on the progress tracking

page (Figure 58). The upgrade process should not be interrupted. Interruption of this process

can result in a corrupt main software image, which will result in the recovery image been

booted at the next reset cycle.

Figure 58 - Software Download Progress Indicator

Figure 59 - Software Upgrade Complete