4 remote leds and recovery switch, 5 cables and connectors, Remote leds and recovery switch – Motorola MotoWI4 PTP 600 Series User Manual

Page 36: Cables and connectors, Figure 11 - remote led and recovery switch wiring, 4 “remote leds and, Recovery switch

Advertising
background image

34

3.3.4

Remote LEDs and Recovery Switch

The PTP 600 Series Bridge PIDU Plus provides a facility to connect remote LEDs and

Recovery switch allowing the PIDU Plus to be mounted inside an enclosure. At the left hand

end of the PIDU Plus under the ODU connection cover can be found a PCB header and three

jumpers. Jumpers J906 and J907 should be removed and connection to the remote LEDs and

Recovery switch made to J908 as shown in Figure 11.

Figure 11 - Remote LED and Recovery Switch Wiring

3.3.5

Cables and connectors

The cable used to connect the PTP 600 Series Bridge PIDU Plus to the ODU can be any

standard CAT5e type provided that it is suitable for outdoor deployment. Motorola

recommends that cables to the specification below be used:

NEC/CEC: CMR (ETL) C (ETL) 75C SUN RES OIL RES II

Failure to use the recommended (or equivalent) standard of cable may invalidate the

system’s safety certification.

The cable used to connect the PTP 600 Series Bridge PIDU Plus to the users Network

Equipment can be any standard CAT5e Cable.