The Recovery switch is used to recover the unit from configuration errors or software image

corruption. To put a PTP 600 Series Bridge into Recovery mode the Recovery switch should

be pressed then the power applied. The Recovery switch should be kept pressed for at least

20 seconds after the power has been applied. Full instruction on the recovery mode can be

found in section 9 “Recovery Mode”.

A simple reboot can be performed by removing and re-applying the mains power to the PTP

600 Series Bridge PIDU Plus.

On the left hand side of the PIDU Plus, 48V DC input and output connections can be found.

These are used to power the PTP 600 Series Bridge from an external DC source or to

provide a level of power supply redundancy, as shown in Section 1.3.3 “Redundancy and

Alternate Powering Configurations”.

WARNING When using alternate DC supplies the supply MUST comply with the following

requirements:

• The voltage and polarity is correct and is applied to the correct terminals in the PIDU Plus
• The power source is rated as SELV
• The power source is rated to supply at least 1A continuously, and
• The power source cannot provide more than the Energy Hazard Limit as defined by

IEC/EN/UL6090, Clause 2.5, Limited Power (The Energy Hazard Limit is 240VA)

Also on the left hand side of the PTP 600 Series Bridge PIDU Plus, connectors and jumpers

can be found that allow the remote connection of power LED, Ethernet LED and Recovery

switch. The connection instructions can be found in Section 1.3.4 “Remote LEDs and

Recovery Switch”

The input supply range for the 600 Series PIDU Plus is 100V-240V AC, 47-63Hz. Mains

connection to the PIDU Plus is made using a standard “figure of eight” mains lead as shown

in Figure 6.

Figure 6 – PTP 600 Series Bridge PIDU Plus Power Input