50

Modulation Mode /

Payload Type

Maximum

Aggregate

Data Rate

10

11

(Mbit/s)

Threshold

Value

(dBm)

Output

Power

(dBm)

Maximum Link

Loss

(dB)

256QAM 0.81 dual

300.2

-59.1

+18

124.1

64QAM 0.92 dual

252.9

-62.0

+18

127.0

64QAM 0.75 dual

206.7

-68.1

+18

133.1

16QAM 0.87 dual

160.8

-71.0

+20

138.0

16QAM 0.63 dual

115.6

-75.2

+22

144.2

16QAM 0.63 single

57.8

-79.3

+22

148.3

QPSK 0.87 single

40.2

-81.6

+23

151.6

QPSK 0.63 single

28.9

-84.6

+24

155.6

BPSK 0.63 single

14.4

-88.1

+25

160.1

256QAM 0.81 single

150.1

-64.0

+18

129.0

64QAM 0.92 single

126.4

-65.9

+18

130.9

64QAM 0.75 single

103.3

-71.7

+18

136.7

16QAM 0.87 single

80.4

-74.8

+20

141.8

Table 8 - 5.8GHz Aggregate Ethernet throughput rate versus maximum link loss

The full calculation is relatively complicated and thus Motorola has supplied a link estimator

that calculates the radio propagation and reliability of NLOS links using the PTP 600 Series

Bridge equipment.

A more detailed discussion on data rates can be found in Section 16.