The following diagrams (Figure 93 & Figure 94) show this zoning pictorially:

Equipment mounted in Zone A should be capable of carrying the full lightning current.

Mounting of the ODU in Zone A is not recommended. Mounting in Zone A should only be

carried out observing the rules governing installations in Zone A

26

Failure to do so may put

structures, equipment and life at risk.

Equipment mounted in Zone B should be grounded using grounding wire of at least 10 AWG.

This grounding wire should be connected to a grounding rod or the building grounding system

before entry in to building.

The 600 Series bridge ODU grounding point can be found on the bottom of the unit. The 600

Series Bridge is supplied with an appropriate grounding lug for attachment to the ODU.

11.2 Detailed Installation

The recommended components for an installation protected for nearby strikes are:

• Grounding Kits — Andrew Type 223158-2 (

http://www.andrew.com

UT

)

• Screened CAT 5e Cable also known as Shielded CAT 5e or CAT 5e STP (Shielded

Twisted Pair)

• NB: Only use Outdoor rated, gel filled CAT5e if it contains a shield.
• Surge Arrestor: Transtector Type ALPU-ORT - 4 per link (www.transtector.com)
• Grounding Stake
• RJ45 screened connectors
• 8 AWG Grounding Cable – Minimum size, preferably 6 or 4

NOTE: There may be a local regulatory requirement to cross bond the CAT 5e cable at

regular intervals to the mast. This may be as frequent as every 10 meters (33 feet)

26

Local regulations may also require the fitting of the 8 AWG ground wire referred below.