5 - 9

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial
value

Unit

Setting

range

Control

mode

Internal speed command 2

Used to set speed 2 of internal speed commands.

S

9

SC2

Internal speed limit 2

Used to set speed 2 of internal speed limits.

500

r/min

0 to

instan-

taneous

permi-

ssible

speed

T

Internal speed command 3

Used to set speed 3 of internal speed commands.

S

10

SC3

Internal speed limit 3

Used to set speed 3 of internal speed limits.

1000

r/min

0 to

instan-

taneous

permi-

ssible

speed

T

11

STA

Acceleration time constant

Used to set the acceleration time required to reach the rated speed
from 0r/min in response to the analog speed command and internal
speed commands 1 to 7.

Time

Parameter
No.12 setting

Parameter
No.11 setting

Zero
speed

Rated
speed

Speed

If the preset speed command is
lower than the rated speed,
acceleration/deceleration time
will be shorter.

For example for the servo motor of 3000r/min rated speed, set 3000
(3s) to increase speed from 0r/min to 1000r/min in 1 second.

0

12

STB

Deceleration time constant

Used to set the deceleration time required to reach 0r/min from the
rated speed in response to the analog speed command and internal
speed commands 1 to 7.

0

ms

0

to

20000

S T

B

asi

c p

ara

m

et

ers

13

STC

S-pattern acceleration/deceleration time constant

Used to smooth start/stop of the servo motor.
Set the time of the arc part for S-pattern acceleration/deceleration.

STA: Acceleration time constant (parameter No.11)
STB: Deceleration time constant (parameter No.12)
STC: S-pattern acceleration/deceleration time con-
stant (parameter No.13)

Speed command

S

e

rv

o mo

tor

S

pee

d

0r/min

STC

STA

STC

STC

STB

STC

Time

Long setting of STA (acceleration time constant) or STB (deceleration time
constant) may produce an error in the time of the arc part for the setting of the
S-pattern acceleration/deceleration time constant.
The upper limit value of the actual arc part time is limited by

At the setting of STA 20000, STB 5000 and STC 200,
the actual arc part times are as follows:

for acceleration or by

for deceleration.

(Example)

During acceleration: 100[ms]

2000000

20000

100[ms] 200[ms].

Limited to 100[ms] since

During deceleration: 200[ms]

2000000

5000

400[ms] 200[ms].

200[ms] as set since

2000000

STA

2000000

STB

0

ms

0

to

1000

S T