3 - 47

3. SIGNALS AND WIRING

(2) For 1-phase 100 to 120VAC or 1-phase 230VAC power supply

RA

OFF

ON

MC

MC

SK

NFB

MC

L

1

L

2

L

3

L

11

L

21

EMG

SON

SG

VDD

COM

ALM

RA

Power supply
1-phase 100 to
120VAC or
1-phase 230VAC

Emergency stop

Servo-on

(Note)

Servo amplifier

Trouble

Emergency
stop

Note. Not provided for 1-phase 100 to 120VAC.