Options and auxiliary equipment – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 274

Advertising
background image

13 - 49

13. OPTIONS AND AUXILIARY EQUIPMENT

(d) Line noise filter (FR-BLF, FR-BSF01)

This filter is effective in suppressing noises radiated from the power supply side and output side of
the servo amplifier and also in suppressing high-frequency leakage current (zero-phase current)
especially within 0.5MHz to 5MHz band.

Connection diagram

Outline drawing [Unit: mm] ([Unit: in.])

4.5(

0.

1

8

)

Approx.110(4.33)

A

ppro

x

22

.5(

0

.8

9

)

A

p

pro

x

.65(

2.5

6

)

Approx.65(2.56)

2- 5(0.20)

Approx.95 0.5(3.74 0.02)

33(1.30)

11

.2

5

0.5

FR-BSF01(for MR-J2S-200A or less)

(0

.4

4

0

.02

)

Wind the 3-phase wires by the equal number of times in the
same direction, and connect the filter to the power supply side
and output side of the servo amplifier.
The effect of the filter on the power supply side is higher as the
number of winds is larger. The number of turns is generally four.
If the wires are too thick to be wound, use two or more filters
and make the total number of turns as mentioned above.
On the output side, the number of turns must be four or less.
Do not wind the grounding wire together with the 3-phase wires.
The filter effect will decrease. Use a separate wire for grounding.

Example 2

Two filters are used
(Total number of turns: 4)

Power
supply

Servo amplifier

Line noise
filter

NFB

L

3

L

1

L

2

Example 1

(Number of turns: 4)

Power
supply

NFB

L

1

L

2

L

3

Servo amplifier

Line noise
filter

MC

MC

160(6.30)

180(7.09)

130(5.12)

85(3.35)

80(3.15)

2.3(0.09)

3

5

(1.3

8)

31.5(1.24)

7(0.28)

7(0.28)

FR-BLF(MR-J2S-350A or more)

(e) Radio noise filter (FR-BIF)...for the input side only

This filter is effective in suppressing noises radiated from the power supply side of the servo
amplifier especially in 10MHz and lower radio frequency bands. The FR-BIF is designed for the
input only.

Connection diagram

Outline drawing (Unit: mm) ([Unit: in.])

Make the connection cables as short as possible.
Grounding is always required.
When using the FR-BIF with a single-phase wire,
always insulate the wires that are not used for wiring.

Servo amplifier

NFB

L

3

L

2

L

1

MC

Power
supply

Radio noise
filter FR-BIF

Leakage current: 4mA

29 (1.14)

58 (2.28)

42 (1.

65)

4 (

0

.16)

Red

Blue

White

Green

44 (1.73)

29 (1.14)

7 (0.28)

hole

A

b

o

u

t 30

0

(1

1

.81)

5 (0.20)

Advertising