5 - 18

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

43

*DI2

Input signal selection 2 (CN1B-5)

This parameter is unavailable when parameter No.42 is set to assign
the control change (LOP) to CN1B-pin 5.
Allows any input signal to be assigned to CN1B-pin 5.
Note that the setting digit and assigned signal differ according to the
control mode.

Position
control mode

Input signals of
CN1B-pin 5
selected.

Torque control mode

Speed control
mode

0

Signals that may be assigned in each control mode are indicated
below by their symbols.
Setting of any other signal will be invalid.

Set value

(Note) Control mode

P

S

T

0
1
2
3
4
5
6
7
8
9

SON

SON

SON

RES

RES

RES

PC

PC

TL

TL

SP1

SP1

SP2

SP2

ST1

RS2

ST2

RS1

CR

CR

CR

A

SP3

SP3

B
C
D

TL1

TL1

E

CDP

CDP

CM1
CM2
TL1
CDP

Note. P: Position control mode

S: Speed control mode

T: Torque control mode

0111

Refer to
Name
and
function
column.

P S T

Ex

pan

si

on

par

ame

te

rs

1

44

*DI3

Input signal selection 3 (CN1B-14)

Allows any input signal to be assigned to CN1B-pin 14.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).

Position
control mode

Input signals of
CN1B-pin 14
selected.

Torque control mode

Speed control
mode

0

This parameter is unavailable when parameter No. 42 is set to
assign the control change (LOP) to CN1B-pin 14.

0222

Refer to
Name
and
function
column.

P S T