Parameters – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 136

Advertising
background image

5 - 17

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

39

VDC

Speed differential compensation

Used to set the differential compensation.
Made valid when the proportion control (PC) is switched on.

980

0

to

1000

P S

40

For manufacturer setting
Do not change this value by any means.

0

P S T

41

*DIA Input signal automatic ON selection

Used to set automatic Servo-on (SON) forward rotation stroke end
(LSP) reveres rotation stroke end (LSN).

Servo-on (SON) input selection

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

Reverse rotation stroke end (LSN)
input selection

Forward rotation stroke end
(LSP) input selection

0

0000

Refer to
Name
and
function
column.

P S

P/S
S/T
T/P

E

xp

ansi

on

p

ara

m

et

ers

1

42

*DI1

Input signal selection 1

Used to assign the control mode changing signal input pins and to set
the clear (CR).

Control change (LOP) in-
put pin assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/spe-
ed, speed/torque or torque/posi-
tion change mode.

Set value

0
1

2

Connector pin No.

CN1B-5

CN1B-14

CN1A-8

3

CN1B-7

Clear (CR) selection

0: Droop pulses are cleared on the

leading edge.

1: While on, droop pulses are always cleared.

4

CN1B-8

5

CN1B-9

0 0

0003

Refer to
Name
and
function
column.

P S T

Advertising