Parameters – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 150

Advertising
background image

5 - 31

5. PARAMETERS

(2) Set content

The servo amplifier is factory-set to output the servo motor speed to analog monitor 1 (MO1) and the
torque to analog monitor (MO2). The setting can be changed as listed below by changing the
parameter No.17 value:
Refer to Appendix 2 for the measurement point.

Setting

Output item

Description

Setting

Output item

Description

0

Servo motor speed

8[V]

Max. speed

0 Max. speed

8[V]

CCW direction

CW direction

6

Droop pulses
(Note1)
( 10V/128pulse)

10[V]

0

128[pulse]

10[V]

CCW direction

CW direction

128[pulse]

1

Torque(Note2)

8[V]

Max. torque

0 Max. torque

8[V]

Driving in CW direction

Driving in CCW direction

7

Droop pulses
(Note1)
( 10V/2048pulse)

10[V]

0 2048[pulse]

10[V]

CCW direction

CW direction

2048[pulse]

2

Servo motor speed

8[V]

Max. speed

0

Max. speed

CCW
direction

CW
direction

8

Droop pulses
(Note1)
( 10V/8192pulse)

10[V]

0 8192[pulse]

10[V]

CCW direction

CW direction

8192[pulse]

3

Torque(Note2)

8[V]

Max. torque

0

Max. torque

Driving in

CW direction

Driving in

CCW direction

9

Droop pulses
(Note1)
( 10V/32768pulse)

10[V]

0 32768[pulse]

10[V]

CCW direction

CW direction

32768[pulse]

4

Current command

8[V]

Max. command
current
(Max. torque
command)

0 Max. command

current
(Max. torque
command)

8[V]

CCW direction

CW direction

A

Droop pulses
(Note1)
( 10V/131072pulse)

10[V]

0

131072[pulse]

10[V]

CCW direction

CW direction

131072[pulse]

5

Command pulse
frequency

10[V]

500kpps

0

500kpps

10[V]

CCW direction

CW direction

B

Bus voltage

8[V]

0

400[V]

Note1. Encoder pulse unit.

2. 8V is outputted at the maximum torque.However, when parameter No.28 76 are set to limit torgue, 8V is outputted
at the torque highly limited.

Advertising