Parameters – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 133

Advertising
background image

5 - 14

5. PARAMETERS

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

21

*OP3 Function selection 3 (Command pulse selection)

Used to select the input form of the pulse train input signal.
(Refer to Section 3.4.1.)

Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A/B phase pulse train

Pulse train logic selection
0: Positive logic
1: Negative logic

0 0

0000

Refer to
Name
and
function
column.

P

22

*OP4

0000

P S

Ex

pan

si

on

par

ame

te

rs

1

Function selection 4

Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN) off and choose VC/VLA voltage
averaging.

How to make a stop when forward
rotation stroke end (LSP)
reverse rotation stroke end (LSN)
is valid. (Refer to Section 5.2.3.)

0: Sudden stop
1: Slow stop

Set value

0
1

2

Filtering time [ms]

0

0.444

0.888

3

1.777

VC/VLA voltage averaging

Used to set the filtering time when the
analog speed command (VC) voltage
or analog speed limit (VLA) is imported.
Set 0 to vary the speed to voltage fluctua-
tion in real time. Increase the set value
to vary the speed slower to voltage flu-
ctuation.

4

3.555

0

0

Refer to
Name
and
function
column.

P S T

Advertising