Options and auxiliary equipment – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 242

Advertising
background image

13 - 17

13. OPTIONS AND AUXILIARY EQUIPMENT

(3) Outline dimension drawing

U

V

W

D

100(3.94)

D

(0.2)5

C

E

G

F

2.3(0.09)

Terminal block

Screw : M3.5

Screw : M4

B

A

5

(0.2)

E

13 14

E

(GND)

a

b

[Unit: mm]
([Unit: in])

Tightening torque : 0.8 [N m](7 [lb in])]

Tightening torque : 1.2 [N m](10.6 [lb in])]

Dynamic brake

A

B

C

D

E

F

G

Mass

[kg]([Ib])

Connection

wire [mm

2

]

DBU-11K

200

(7.87)

190

(7.48)

140

(5.51)

20

(0.79)

5

(0.2)

170

(6.69)

163.5

(6.44)

2 (4.41)

5.5

DBU -15K, 22K

250

(9.84)

238

(9.37)

150

(5.91)

25

(0.98)

6

(0.24)

235

(9.25)

228

(8.98)

6 (13.23)

5.5

POINT

Configure up a sequence which switches off the contact of the brake unit
after (or as soon as) it has turned off the servo on signal at a power failure
or failure.
For the braking time taken when the dynamic brake is operated, refer to
Section 12.3.
The brake unit is rated for a short duration. Do not use it for high duty.
When the dynamic brake is used, the power supply voltage is restricted as
indicated below.

3-Phase 170 to 220VAC/50Hz

3-Phase 170 to 242VAC/60Hz