15 - 39

15. ABSOLUTE POSITION DETECTION SYSTEM

(c) ABS data transfer program for X-axis

M8002

D24

K0

DMOV

K1

K0

K3

K0

TO

K1

K100000

K4

K0

DTO

K1

K10000

K7

K0

DTO

K1

K50000

K9

K0

DTO

K1

K1000

K11

K0

TO

K1

K2

K12

K0

TO

K1

D24

K13

K0

DTO

K1

K200

K15

K0

TO

K1

K100000

K19

K0

DTO

1

1

D100

K300000

DMOV

D102

K 250000

DMOV

D104

K0

DMOV

Z

K0

DMOV

D4

K4

DMOV

Setting home position address
to 0

Setting 1PG pulse command
unit

1PG max. speed: 100 kpps

1PG Jog speed: 10 kpps

1PG home position return
speed: 50 kpps

1PG creep speed: 1 kpps

1PG home position return
zero-point count: twice

1PG home position address
setting

1PG acceleration/deceleration
time: 200ms

1PG operation speed:
100kpps

Position move account 1:
300000 pulses

Position move account 2:
250000 pulses

Position move account 3:
0 pulses

Clearing index registers V, Z

Setting "4 times" for check
sum error transmission
frequency

Initial setting

Initial

pulse

(To be continued)