3. SIGNALS AND WIRING

3.13 Power line circuit of the MR-J2S-11KA to MR-J2S-22KA

CAUTION

When the servo amplifier has become faulty, switch power off on the amplifier

power side. Continuous flow of a large current may cause a fire.

Use the trouble (ALM) to switch power off. Otherwise, a regenerative brake

transistor fault or the like may overheat the regenerative brake resistor, causing a

fire.

POINT

The power-on sequence is the same as in Section 5.7.3.

3.13.1 Connection example

Wire the power supply/main circuit as shown below so that power is shut off and the servo-on signal
turned off as soon as an alarm occurs, a servo emergency stop is made valid, a controller emergency stop,
or a servo motor thermal relay alarm is made valid. A no-fuse breaker (NFB) must be used with the input
cables of the power supply.

L

1

L

2

L

3

L

11

L

21

EMG

SON

SG

CN2

U

V

W

U

V

W

M

BU

RA2

BV

BW

MC

SK

ON

MC

NFB

MC

OHS2

OHS1

ALM

COM

VDD

RA1

Servo motor

thermal relay

RA2

Alarm

RA1

emergency stop

OFF

3-phase
200 to 230VAC

Servo amplifier

(Note1)

Dynamic

break

Servo motor

HA-LFS series

Encoder

Fan

(Note2)

Servo motor

thermal relay

24VDC
power supply

Emergency stop
servo-on

MR-JHSCBL M

cable

2. There is no BW when the HA-LFS11K2 is used.

Note 1. When using the external dynamic break, refer to section 13.1.4.

Trouble

3. Always connect P-P

1

. (Factory-wired.) When using the power factor improving DC reactor,

refer to Section 13.2.4