Conformance with ul/c-ul standard – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 11

Advertising
background image

A - 10

CONFORMANCE WITH UL/C-UL STANDARD

(1) Servo amplifiers and servo motors used

Use the servo amplifiers and servo motors which comply with the standard model.

Servo amplifier

:MR-J2S-10A to MR-J2S-22KA
MR-J2S-10A1 to MR-J2S-40A1

Servo motor

:HC-KFS
HC-MFS
HC-SFS
HC-RFS
HC-UFS
HA-LFS
HC-LFS

(2) Installation

Install a fan of 100CFM (2.8m

3

/min) air flow 4 in (10.16 cm) above the servo amplifier or provide

cooling of at least equivalent capability.

(3) Short circuit rating

This servo amplifier conforms to the circuit whose peak current is limited to 5000A or less. Having
been subjected to the short-circuit tests of the UL in the alternating-current circuit, the servo
amplifier conforms to the above circuit.

(4) Capacitor discharge time

The capacitor discharge time is as listed below. To ensure safety, do not touch the charging section for
15 minutes after power-off.

Servo amplifier

Discharge time

[min]

MR-J2S-10A(1) 20A(1)

1

MR-J2S-40A(1) 60A

2

MR-J2S-70A to 350A

3

MR-J2S-500A 700A

5

MR-J2S-11KA

4

MR-J2S-15KA

6

MR-J2S-22KA

8

(5) Options and auxiliary equipment

Use UL/C-UL standard-compliant products.

(6) Attachment of a servo motor

For the flange size of the machine side where the servo motor is installed, refer to “CONFORMANCE
WITH UL/C-UL STANDARD” in the Servo Motor Instruction Manual.

(7) About wiring protection

For installation in United States, branch circuit protection must be provided, in accordance with the
National Electrical Code and any applicable local codes.
For installation in Canada, branch circuit protection must be provided, in accordance with the Canada
Electrical Code and any applicable provincial codes.

Advertising