5 - 1

5. PARAMETERS

5. PARAMETERS

CAUTION

Never adjust or change the parameter values extremely as it will make operation

instable.

5.1 Parameter list

5.1.1 Parameter write inhibit

POINT

After setting the parameter No. 19 value, switch power off, then on to
make that setting valid.

In the MR-J2S-A servo amplifier, its parameters are classified into the basic parameters (No. 0 to 19),
expansion parameters 1 (No. 20 to 49) and expansion parameters 2 (No.50 to 84) according to their
safety aspects and frequencies of use. In the factory setting condition, the customer can change the
basic parameter values but cannot change the expansion parameter values. When fine adjustment, e.g.
gain adjustment, is required, change the parameter No. 19 setting to make the expansion parameters
write-enabled.
The following table indicates the parameters which are enabled for reference and write by the setting of

parameter No. 19. Operation can be performed for the parameters marked .

Parameter No. 19 setting

Operation

Basic parameters

No. 0 to No. 19

Expansion parameters 1

No. 20 to No. 49

Expansion parameters 2

No. 50 to No. 84

Reference

0000

(initial value)

Write

Reference

No. 19 only

000A

Write

No. 19 only

Reference

000B

Write

Reference

000C

Write

Reference

000E

Write

Reference

100B

Write

No. 19 only

Reference

100C

Write

No. 19 only

Reference

100E

Write

No. 19 only