5 - 26

5. PARAMETERS

5.2 Detailed description

5.2.1 Electronic gear

CAUTION

Wrong setting can lead to unexpected fast rotation, causing injury.

POINT

The guideline of the electronic gear setting range is 50

1

CDV

CMX

500.

If the set value is outside this range, noise may be generated during
acceleration/ deceleration or operation may not be performed at the preset
speed and/or acceleration/deceleration time constants.

The following specification symbols are required to calculate the electronic
gear.

(1) Concept of electronic gear

The machine can be moved at any multiplication factor to input pulses.

CDV

CMX

Parameter No.4

Parameter No.3

Electronic gear

Feedback pulse

CMX
CDV

Deviation
counter

Motor

Encoder

In

p

u

t p

u

lse tr

ain

The following setting examples are used to explain how to calculate the electronic gear:

POINT

The following specification symbols are required to calculate the electronic
gear
Pb : Ballscrew lead [mm]
n : Reduction ratio
Pt : Servo motor resolution [pulses/rev]

0

: Travel per command pulse [mm/pulse]

S : Travel per servo motor revolution [mm/rev]

: Angle per pulse [ /pulse]
: Angle per revolution [ /rev]

(a) For motion in increments of 10 m per pulse

Machine specifications

Ballscrew lead Pb 10 [mm]
Reduction ratio: n 1/2
Servo motor resolution: Pt 131072 [pulses/rev]

Servo motor
131072 [pulse/rev]

n

NM

NL

Pb 10[mm]

n NL/NM

1/2

CDV

CMX

0

Pt

S

0

Pt

n Pb

10 10

3

1/2 10

131072

262144

1000

32768

125

Hence, set 32768 to CMX and 125 to CDV.