2 analog monitor, Parameters – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 149

Advertising
background image

5 - 30

5. PARAMETERS

5.2.2 Analog monitor

The servo status can be output to two channels in terms of voltage. The servo status can be monitored
using an ammeter.

(1) Setting

Change the following digits of parameter No.17:

Analog monitor (MO1) output selection
(Signal output to across MO1-LG)

Analog monitor (MO2) output selection
(Signal output to across MO2-LG)

Parameter No. 17

0

0

Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The setting

range is between 999 and 999mV.

Parameter No.

Description

Setting range [mV]

31

Used to set the offset voltage for the analog monitor 1 (MO1).

32

Used to set the offset voltage for the analog monitor 2 (MO2)
output.

999 to 999