Display and operation, 1 display flowchart – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 154

Advertising
background image

6 - 1

6. DISPLAY AND OPERATION

6. DISPLAY AND OPERATION

6.1 Display flowchart

Use the display (5-digit, 7-segment LED) on the front panel of the servo amplifier for status display,
parameter setting, etc. Set the parameters before operation, diagnose an alarm, confirm external
sequences, and/or confirm the operation status. Press the "MODE" "UP" or "DOWN" button once to move to
the next screen.
To refer to or set the expansion parameters, make them valid with parameter No. 19 (parameter write
disable).

Cumulative feedback
pulses [pulse]

Motor speed
[r/min]

Droop pulses
[pulse]

Cumulative command
pulses [pulse]

Command pulse
frequency [kpps]

Speed command voltage
Speed limit voltage[mV]

Torque limit voltage
Torque command voltage

Regenerative load
ratio [%]

Effective load ratio
[%]

Peak load ratio
[%]

Within one-revolution
position low [pulse]

ABS counter
[rev]

Load inertia moment
ratio [times]

Sequence

External I/O
signal display

Output signal
forced output

Test operation
Jog feed

Test operation
Positioning operation

Test operation
Motor-less operation

Software version L

Software version H

Automatic VC offset

Current alarm

Last alarm

Second alarm in past

Third alarm in past

Fourth alarm in past

Fifth alarm in past

Sixth alarm in past

Parameter error No.

Parameter No. 0

Parameter No. 1

Parameter No. 18

Parameter No. 19

Parameter No. 20

Parameter No. 21

Parameter No. 48

Parameter No. 49

(Note)

Note. The initial status display at power-on depends on the control mode.

Position control mode: Cumulative feedback pulses(C), Speed control mode: Motor speed(r),
Torque control mode: Torque command voltage(U)
Also, parameter No. 18 can be used to change the initial indication of the status display at power-on.

MODE

button

DOWN

UP

Status display

Diagnosis

Basic
parameters

Expansion
parameters 1

Alarm

Expansion
parameters 2

Parameter No. 50

Parameter No. 51

Parameter No. 83

Parameter No. 84

Instantaneous torque
[%]

Within one-revolution

position, high [100 pulses]

Bus voltage [V]

Test operation

Machine analyzer operation

Motor series ID

Motor type ID

Encoder ID

[mV]

Advertising