6 - 15

6. DISPLAY AND OPERATION

6.8.3 Positioning operation

POINT

The MR Configurator (servo configuration software) is required to perform
positioning operation.

Positioning operation can be performed once when there is no command from the external command
device.

(1) Operation

Connect EMG-SG to start positioning operation and connect VDD-COM to use the internal power
supply.
Pressing the "Forward" or "Reverse" click on the MR Configurator (servo configuration software) starts
the servo motor, which will then stop after moving the preset travel distance. You can change the
operation conditions on the MR Configurator (servo configuration software). The initial conditions and
setting ranges for operation are listed below:

Item

Initial setting

Setting range

Travel distance [pulse]

10000

0 to 9999999

Speed [r/min]

200

0 to instantaneous permissible speed

Acceleration/deceleration time constant [ms]

1000

0 to 50000

How to use the buttons is explained below:

Button

Description

"Forward"

Click to start positioning operation CCW.

"Reverse"

Click to start positioning operation CW.

"Pause"

Click during operation to make a temporary stop. Click the
"Pause" button again erases the remaining distance.
To resume operation, press the click that was pressed to start
the operation.

If the communication cable is disconnected during positioning operation, the servo motor will come
to a sudden stop.

(2) Status display

You can monitor the status display even during positioning operation.

Advertising