4 gain changing operation, Special adjustment functions – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 189

Advertising
background image

8 - 8

8. SPECIAL ADJUSTMENT FUNCTIONS

8.5.4 Gain changing operation

This operation will be described by way of setting examples.

(1) When you choose changing by external input

(a) Setting

Parameter No.

Abbreviation

Name

Setting

Unit

6

PG1

Position control gain 1

100

rad/s

36

VG1

Speed control gain 1

1000

rad/s

34

GD2

Ratio of load inertia moment to
servo motor inertia moment

4

0.1 times

35

PG2

Position control gain 2

120

rad/s

37

VG2

Speed control gain 2

3000

rad/s

38

VIC

Speed integral compensation

20

ms

61

GD2B

Ratio of load inertia moment to
servo motor inertia moment 2

100

0.1 times

62

PG2B

Position control gain 2
changing ratio

70

%

63

VG2B

Speed control gain 2 changing
ratio

133

%

64

VICB

Speed integral compensation
changing ratio

250

%

65

CDP

Gain changing selection

0001

(Changed by ON/OFF of

pin CN1A-8)

67

CDT

Gain changing time constant

100

ms

(b) Changing operation

OFF

ON

OFF

Gain changing
(CDP)

Change of
each gain

Before-changing gain

After-changing gain

CDT 100ms

Position control gain 1

100

Speed control gain 1

1000

Ratio of load inertia moment
to servo motor inertia moment

4.0

10.0

4.0

Position control gain 2

120

84

120

Speed control gain 2

3000

4000

3000

Speed integral compensation

20

50

20

Advertising