3 remedies for warnings, Troubleshooting, Caution – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 206

Advertising
background image

10 - 13

10. TROUBLESHOOTING

10.2.3 Remedies for warnings

CAUTION

If an absolute position counter warning (AL.E3) occurred, always make home

position setting again. Otherwise, misoperation may occur.

POINT

When any of the following alarms has occurred, do not resume operation by

switching power of the servo amplifier OFF/ON repeatedly. The servo amplifier

and servo motor may become faulty. If the power of the servo amplifier is

switched OFF/ON during the alarms, allow more than 30 minutes for cooling

before resuming operation.

Excessive regenerative warning (AL.E0)

Overload warning 1 (AL.E1)

If Servo emergency stop warning (AL.E6) or ABS servo-on warning (AL.EA) occurs, the servo off status is
established. If any other warning occurs, operation can be continued but an alarm may take place or
proper operation may not be performed. Use the optional MR Configurator (servo configuration software)
to refer to the cause of warning.

Display

Name

Definition

Cause

Action

1. Battery cable is open.

Repair cable or changed.

AL.92 Open battery

cable warning

Absolute position
detection system battery
voltage is low.

2. Battery voltage supplied from the servo
amplifier to the encoder fell to about 3.2V
or less. (Detected with the encoder)

Change battery.

1. Droop pulses remaining are greater

than the in-position range setting.

Remove the cause of droop pulse
occurrence

2. Command pulse entered after clearing

of droop pulses.

Do not enter command pulse
after clearing of droop pulses.

AL.96 Home position

setting warning

Home position setting
could not be made.

3. Creep speed high.

Reduce creep speed.

AL.9F Battery warning Voltage of battery for

absolute position
detection system reduced.

Battery voltage fell to 3.2V or less.
(Detected with the servo amplifier)

Change the battery.

AL.E0 Excessive

regenerative
warning

There is a possibility that
regenerative power may
exceed permissible
regenerative power of
built-in regenerative
brake resistor or
regenerative brake
option.

Regenerative power increased to 85% or
more of permissible regenerative power of
built-in regenerative brake resistor or
regenerative brake option.

Checking method

Call the status display and check
regenerative load ratio.

1. Reduce frequency of

positioning.

2. Change regenerative brake

option for the one with larger
capacity.

3. Reduce load.

AL.E1 Overload

warning

There is a possibility that
overload alarm 1 or 2
may occur.

Load increased to 85% or more of overload
alarm 1 or 2 occurrence level.

Cause, checking method

Refer to AL.50,51.

Refer to AL.50, AL.51.

1. Noise entered the encoder.

Take noise suppression
measures.

Absolute position encoder
pulses faulty.

2. Encoder faulty.

Change servo motor.

AL.E3 Absolute position

counter warning

The multi-revolution
counter value of the
absolute position encoder
exceeded the maximum
revolution range.

3. The movement amount from the home

position exceeded a 32767 rotation or -
37268 rotation in succession.

Make home position setting
again.

Advertising