4 encoder cable flexing life, Characteristics – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 224

Advertising
background image

12 - 7

12. CHARACTERISTICS

Use the dynamic brake at the load inertia moment indicated in the following table. If the load inertia
moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility that the
load inertia moment may exceed the value, contact Mitsubishi.

Servo amplifier

Load inertia moment ratio [times]

MR-J2S-10A to MR-J2S-200A

MR-J2S-10A1 to MR-J2S-40A1

30

MR-J2S-350A

16

MR-J2S-500A MR-J2S-700A

15

MR-J2S-11KA to MR-J2S-22KA

(Note)

30

Note. The value assumes that the external dynamic brake is used.

12.4 Encoder cable flexing life

The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed
values, provide a little allowance for these values.

1 10

7

5 10

7

1 10

8

5 10

6

1 10

6

5 10

5

1 10

5

5 10

4

1 10

4

5 10

3

1 10

3

a

b

F

lexi

ng l

if

e

[

ti

m

es]

4

7

10

20

40

70 100

200

Flexing radius [mm]

a : Long flexing-life encoder cable
MR-JCCBL M-H
MR-JHSCBL M-H
MR-ENCBL M-H

b : Standard encoder cable
MR-JCCBL M-L
MR-JHSCBL M-L

Advertising