2 brake unit, Options and auxiliary equipment – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 235

Advertising
background image

13 - 10

13. OPTIONS AND AUXILIARY EQUIPMENT

13.1.2 Brake unit

POINT

The brake unit and resistor unit of other than 200V class are not
applicable to the servo amplifier.
The brake unit and resistor unit of the same capacity must be combined.
The units of different capacities may result in damage.
The brake unit and resistor unit must be installed on a vertical surface in
the vertical direction. If they are installed in the horizontal direction or on
a horizontal surface, a heat dissipation effect reduces.
The temperature of the resistor unit casing rises to higher than 100
(212 ). Do not cause cables and combustibles to make contact with the
casing.

The brake unit is the integration of the regenerative control and resistor and is connected to the bus
(across P-N) of the servo amplifier. As compared to the MR-RB regenerative brake option, the brake unit
can return larger power. Hence, use the this brake unit when the MR-RB cannot provide sufficient
regenerative brake capability.
When using the brake unit, set "01

" in parameter No.0.

(1) Selection

Brake unit

Resistor unit

Permissible Continuous

Power [kw]

Max. Instantaneous

Power [kw]

Applicable Servo Amplifier

FR-BU-15K

FR-BR-15K

0.99

16.5

FR-BU-30K

FR-BR-30K

1.99

33.4

FR-BU-55K

FR-BR-55K

3.91

66.8

MR-J2S-500A
MR-J2S-700A

MR-J2S-11KA
MR-J2S-15KA
MR-J2S-22KA

(2) Connection example

MC

NFB

L

1

L

2

L

3

L

11

L

21

C

N

PR

HA

HB

HC

PR

P

TH1

TH2

THS

P

P

1

Power supply

3-phase

200 to 300VAC

No-fuse breaker

Servo amplifer

(Note2)

FR-BU brake unit

Alarm
output

FR-BR resistor unit

(Note3)

(Note1)

(Note1)

Note 1. Make up the external sequence to switch the power off when an alarm occurs or when the thermal relay is actuated.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative brake resistor connected to P
terminal and C terminal.
3. When using servo ampliflers of 11kw to 22kw, always connect P-P

1

.(Factory-wired.) When using the power factor improving DC reactor,

refer to Section 13.2.4